Roof Framing Geometry Proposition – Axioms # 8:
The intersection of the Rafter Run Line & TC Line locates Hip Rafter DP Line.
C5m Main Hip Rafter Backing Angle = 12.92097 C5a Adjacent Hip Rafter Backing Angle = 12.92097
Valley Sleeper Saw Blade Bevel Angle = 90° - (C5m + C5a) = 64.15807
The California Valley Sleeper Bevel offset dimension is:
Material Depth × tan(Valley Sleeper Saw Blade Bevel Angle)
in this example the material thickness is 1.5"
1.5" × tan(64.15807) = 3.09711" or 3 1/8"
In this picture you can see the red snap line on the face of the 2x12 valley sleeper material for the California Valley Sleeper Bevel offset dimension. However, the Valley Sleeper Saw Blade Bevel Angle was greater than the bevel angle settings on my saw, so I use 90° - 64.15807° = 25.84193° or 25.8° and cut the material from the edge of the material instead of using the 64.15807° on the face of the material. First I used my 7 1/4" SkillSaw to cut the bevel angle, then I used my Bigfoot Saw with the 10" blade to finish off the cut. You could also use a Bigfoot saw with a swing table to make the 64.15807° bevel angle on the face of the material.
California Valley Sleeper with the roof sheathing miter angle on the face of the sleeper and the bevel angle for the plumb cut using the roof slope angle.